Ultraviolet generator use specification
Leave a message
1. Do not start the device when there is no water in the disinfection channel or the water volume does not reach the operating water level.
2. Regardless of whether there is an automatic cleaning mechanism, the glass casing must be manually cleaned regularly according to the quality of sewage and the actual treatment of on-site sewage;
3. The UV lamp, glass sleeve, glass sleeve cleaning ring, and light intensity sensor should be replaced regularly;
4. Silt in the channel in front of the overflow weir should be removed regularly;
5. The effective water level before the overflow weir should be met to ensure the submersion depth of the UV lamp;
6. Personnel working or visiting the ultraviolet disinfection process system must be well protected; Non-staff are strictly prohibited from staying in the disinfection work area;
7. The lamp source module and the control cabinet must be strictly grounded to avoid electric shock accidents;
8. Wear rubber gloves and protective glasses when manually cleaning the glass sleeve;
9. The transmission rate of sewage disinfected by ultraviolet light should be greater than 30%.