Home - Knowledge - Details

How to effectively reduce energy consumption in sewage treatment plants

I. Choose the right Air Blower

When selecting a Air Blower, first of all, it should have sufficient pressure. The blower oxygenates the aeration tank and must overcome the pressure caused by the resistance of the pipeline, the liquid level elevation of the aeration tank, blockage of the aeration head, changes in water level, etc.

Air Blower flow is a key parameter for Air Blower selection. In the small flow range, Roots blowers have low cost and good performance-price ratio. In the medium flow range, multi-stage centrifugal fans are slightly more expensive than Roots blowers, but have low energy consumption and high efficiency. High, good value for money. In the large flow range, single-stage centrifugal fans have the lowest cost and lowest energy consumption.

At present, the main Air Blower include Roots blowers, multi-stage centrifugal fans, single-stage height centrifugal fans, air suspension fans, magnetic levitation fans, etc.

When the rated power is ≤74kw, the Roots blower is cost-effective and practical.

When the rated power is 90-132kw, multi-stage centrifugal fans have price advantages.

When the rated power is >132kw, the single-stage high-speed centrifugal fan is the most cost-effective.

II. Precise control of aeration volume

At present, the aeration adjustment method of most sewage treatment plants is controlled by manual adjustment valves, which has low control accuracy and high labor intensity.

The precise aeration flow control system is an integrated intelligent control system that provides automated and precise aeration solutions for the aeration system.

The precise aeration control system uses a biological treatment model to calculate the current aeration requirements and perform precise control according to the requirements. The aeration system will continuously monitor the aeration volume, timely monitor small changes in pressure in the system, and the control system will adjust in a timely manner.

III. Choose the right water pump

Inlet water lift pumps, return water pumps, sludge pumps, etc. play a vital role in the sewage treatment process. They are also large energy-consuming equipment. In order to keep the water pump in efficient working condition, the appropriate water pump should be selected according to the characteristic curve of the pipeline system.

It is impossible for a water pump motor to convert all the input energy into mechanical energy. The motor efficiency is generally 70%-96%. The motor generally has low efficiency when working under low load. The motor efficiency is generally higher when the load is ≥75%, and the efficiency is lower when the load is <50%.

IV. Reasonably reduce the pump head

1. The system tries to achieve one lift to avoid lifting the sewage multiple times, which increases energy consumption, and makes full use of gravity to make the sewage flow naturally.

2. Reasonably design the structure's water inlet and outlet forms and the connection methods between pipes, and rationally select the form of equipment to reduce head loss during the treatment process. The pipeline layout between various structures should be compact and concise to avoid unnecessary turns and long-distance transportation, which not only reduces water head loss, but also reduces energy consumption.

3. Modify the fixed overflow weir to an adjustable overflow weir, and modify the non-submerged overflow weir to a flooded overflow weir. The drop can be reduced by 25-30cm.

4. When actual conditions permit, certain units can be built together so that the pools in each unit are connected end to end, so that the water flow is normal and the head loss is minimized. Reasonably design the layout of the pool to minimize hydraulic transportation links and reduce energy consumption.

V. Regular maintenance and overhaul

Like other mechanical equipment, the wear of water pumps increases with the extension of operating time, and the flow rate and pump head will also decrease. Although timely maintenance and inspection increase additional inspection costs, after inspection, the surface roughness of the water pump structure is eliminated. It can improve the efficiency of the water pump and keep the water pump working efficiently.

Like other mechanical equipment, the wear of water pumps increases with the extension of operating time, and the flow rate and pump head will also decrease. Although timely maintenance and inspection increase additional inspection costs, after inspection, the surface roughness of the water pump structure is eliminated. It can improve the efficiency of the water pump and keep the water pump working efficiently.

VI. Choose appropriate sludge dewatering machine

1. Selection of sludge dehydrator

Choosing a reasonable type and model of sludge treatment equipment is an important way to reduce the sludge unit. Common sludge dewatering machine generally includes: filter press, bag deslimer, centrifugal deslimer and screw press dehydrator. In terms of energy consumption:

Compared with belt filter press and filter press, centrifugal dehydrators use less flocculant and cleaning water. The disadvantage is that they consume large amounts of electricity.

When sludge treatment is the same, the screw press dehydrator can save 85% of energy compared to other dehydration equipment, and the floor space is only half the same. In terms of surface cleaning, it saves 95% of water than the belt filter press.

2. Selection of flocculant

Try to use high-efficiency flocculants to improve quality and performance, and control the dosage to 0.25% of the sludge to effectively reduce the cost of sludge dehydration.

3. Reasonably adjust equipment parameters

Taking the screw press dehydrator as an example, adjusting the mud outlet baffle can adjust the dryness and wetness of the mud. According to local regulations and sludge transportation or landfill requirements, adjust the appropriate sludge dryness, which can not only ensure the dehydration effect, but also reduce energy consumption.

You can choose to use a variable frequency motor to adjust the speed for different water volumes and sludge concentrations. This can also reduce energy consumption and reflect the application value of variable frequency speed regulation in energy saving and consumption reduction.